HK-7200A Toxic Gas Detector




Supplies category:Gas Detector

Material code:HK-7200A

Manufacturers,:HKY Technology Co.,Ltd.



  • Introduction to the
  • The characteristics of
  • Technical indicators
  • configuration
The Ex HK-7200A Toxic Gas Detector, based on electrochemical principle, is designed for continuous detecting and monitoring of hazardous gas leaks in ambient air and provides a 4~20mA output signal that can be connected to a controller, PLC,DCS or similar instrumentation.
 . ADVANCED MCU TECHNOLOGY.
 . SMT AND INGETAL DESIGN—Enhance performance and reliability.
 . CURRENT TRANSMISSION–Extremely extends the distance of signal transmission. 
 . CENTRALIZED POWER SUPPLY AND REGIONAL POWER SUPPLY 
 . LED DISPLAY—Display real-time concentration and operating statues of detector.
 . SIGNAL TRANSMISSION—Send measured concentration signal to controller.
 . INDOOR AND OUTDOOR USE—Suitable for the harshest environmental conditions.
 . UNIQUE MAGNETIC PEN DESIGN—Operate detector through magnetic pen. 
 . IMPORTED CATALYTIC COMBUSTION SENSOR—Advanced performance with stable measurement, high sensitivity, anti-poisoning, and resist influence. 
 . SENSOR DIAGNOSTIC FUNCTION—Provide alarm and prompt while sensor fault or ageing.

Display

LED

Display real-time concentration and operating statues of detector

(including high alarm,low alarm,and fault alarm)

Measurement

Toxic Gases

Principle

Electrochemical

Sample Method

Diffusion

Measurement

O2, CO, H2S, H2, Cl2, SO2 and other toxic gases

Measurement Range

See below (depend on power requirements)

AccuracyP

±5%F.S

Response Time (T90)

≤60 sec at 25oC

Alarm Configuration

Two levels alarm,the alarm concentration programmable

Ambient Temperature

-20 to 50oC

Ambient Humidity

≤93%RH at 40oC (no condensation)

Atmosphere Pressure

86-106KPa

Output Signal

4-20mA

Transmission Distance

≤1000m (2.5mm2)

Power Supply

24±6VDC (centralized power supply or regional power supply)

Connection Method

3-wires

Power Consumption

≤1W

Storage Temperature

-25 to 55oC

Explosion-proof

Exd II CT6

Protection Grade

IP66


Measurement

 

CO

H2S

SO2、、

Cl2

H2

O2

Measure range

(0~500)×
10-6

(0~50) ×10-6

(0~20)×10-6

(0~20)×10-6

(0~500)×10-6

(0~25)%VOL


×

Ask for your quotation

HK-7200A Toxic Gas Detector

Your message

Please try to complete your information so that we can deal with your problem more quickly and efficiently

  • The name*

  • gender*

  • email*

  • Telephone (please do not forget to fill in)*

  • Name of the entity*

  • address*

  • 城市

  • The zip code*

  • countries*

  • provinces*

Your requirements will be transferred to relevant personnel for processing. Clicking "send" indicates that you agree with mettler Toledo to contact you. We will try to meet your requirements and communicate with you about our products and services.
×